Prevent Ice Dams With Air Sealing and Insulation. During snowy winters, many northern homes are plagued by ice dams. If your house suffers from wet ceilings during the winter, you may be ready to call up a contractor. Be careful, though: since most contractors don’t understand the causes of ice dams, they often suggest the wrong solution. Ice dams form when a home’s escaping heat warms the roof sheathing. Material, usually plywood or oriented strand board (OSB), but sometimes wooden boards, installed on the exterior of wall studs, rafters, or roof trusses; siding or roofing installed on the sheathing—sometimes over strapping to create a rainscreen. Water trickles down the roof until it reaches the cold roofing over the eaves, where it freezes. After a while, the ice at the eaves gets thicker and thicker, forming an ice dam. Eventually, water backs up behind the ice dam. If the water reservoir is large enough, it can back up under the roof shingles and damage ceilings. Image #4, below, depicts the complicated shape of a typical ice dam more accurately than the simplified drawings in Images #2 and #3.)The four possible solutions to ice damming are: Sealing air leaks between the warm interior and the attic or cathedral ceiling. Adding more ceiling insulation. Improving ventilation between the top of the insulation and the roof sheathing. Installing a rubberized membrane under the roofing.
![]() What’s the Difference?: Whole-House Fans vs. Powered Ventilators. Whole-house fans A whole-house fan is an attic-mounted fan that exhausts air from a home at night. Search the history of over 305 billion web pages on the Internet. While the first two of these solutions can reduce or eliminate the problem, the last two solutions are the equivalent of waving a white flag and admitting defeat. Step one: seal the air leaks. Most ice dams are caused by flaws in a home’s air barrier. Building assembly components that work as a system to restrict air flow through the building envelope. Air barriers may or may not act as a vapor barrier. The air barrier can be on the exterior, the interior of the assembly, or both. If escaping indoor air finds its way to the underside of the roof sheathing during the winter, the heated air raises the temperature of the sheathing. That’s bad. One energy expert who made a career of correcting ice- dam problems was the late Tony Woods, a Canadian physicist and founder of Can. Am Building Envelope. Exterior components of a house that provide protection from colder (and warmer) outdoor temperatures and precipitation; includes the house foundation, framed exterior walls, roof or ceiling, and insulation, and air sealing materials. Specialists in Mississauga, Ontario. After diagnosing problems in hundreds of homes, Woods knew from experience that most ice dams were caused by air leaks. I interviewed Woods a few years ago for an article in Energy Design Update. You can’t say to the consumers, ‘Will you please look in your attic?’ — because they don’t want to look into the attic,” Woods told me. Who does the consumer go to when he has a problem? It’s always the roofer. ![]() The roofer will replace any rotten wood and try to talk the consumer into buying a new roof.”Woods recalled one home that was plagued by leaks every winter. The lady had called three roofers in just two or three years,” Woods told me. The first roofer persuaded her to replace the roof.” The following winter, however, her ceiling was once again wet.“The second year, she brought in a second roofer. He said the first roofer hadn’t ventilated properly, and he built a second roof over the first roof. But she still had the same problem. Then, when the third roofer came on, I was called to look at the house. There were pot lights galore. When we said that the problem is not the roof, the lady burst into tears.”Unless you have a blower door handy, the only way to locate air leaks into an attic is to crawl up and look around. Most of the sealing can be handled effectively with two- component polyurethane spray foam,” Woods told me. Usually you have to move some of the insulation aside to expose the top plates. You can seal ducts by spraying, in most instances. Occasionally we will cut pieces of drywall to box the can lights. Also, more than 5. Although Woods often advised homeowners that they needed more insulation, he told me that “most of our work is stuffing and foaming holes.”Step two: check your insulation level. Once you’ve plugged your air leaks, check your insulation levels. The latest version of the International Residential Code requires R- 4. Zones 6, 7, and 8. That area includes northern Idaho, northern Utah, Wyoming, South Dakota, Minnesota, Wisconsin, northern Michigan, upstate New York, Vermont, New Hampshire, and Maine.)In these areas, ceilings need a minimum of 1. If you’re using blown- in fiberglass, you’ll need about 2. R- 4. 9. In climate zones 4 and 5 — an area that includes northern Arizona, northern New Mexico, and Tennessee — you’ll need a minimum of R- 3. That means at least 1. In homes where there isn’t enough room to get R- 3. R- 4. 9 at the perimeter of the attic, the best thing to do is to install as much closed- cell spray polyurethane foam as the space permits. In some cases, it may be necessary to install additional rigid foam insulation on top of the existing roof sheathing. That can only be done if you are replacing the roof.)Two more points about attic insulation: Attic insulation must completely cover the top plates of a home’s exterior walls. Code insulation requirements represent the legal minimum. Most green builders choose to exceed these minimum requirements. Step three: improve ventilation between the insulation and the roof sheathing. Once you’ve done your best with steps 1 and 2, it’s worth considering step 3: ventilation. In the world of ice- dam prevention, ventilation is capitulation. By recommending ventilation, a builder is saying, “I wasn’t able to include enough insulation to prevent the roof sheathing from being warmed by escaping building heat. So I guess I’ll use another method to cool the roof — I’ll ventilate the underside of the roof with exterior air.”Although it is an admission of failure, this type of roof ventilation often makes sense. It’s a kind of insurance. When using roof ventilation to address ice dams, remember: Ventilation should always be the third, not the first, weapon in your arsenal. Distrust any expert who advises using ventilation as the first step toward solving an ice dam problem. If ventilation channels are improved without any attempt to perform air sealing work, ventilation improvements can make an ice dam problem worse or increase a home’s fuel bills. By depressurizing an attic, an effective ridge vent often increases air leakage through the ceiling, bringing more heat than ever against the roof sheathing.)The best ventilation channels include a balance of soffit vents and ridge vents. Attics do not need gable vents. In a cathedral ceiling, provide an air barrier between the top of the insulation and the ventilation channel. Site- built ventilation chutes (foamed or caulked in place) are far preferable to polystyrene Proper- Vents. All attic ventilation systems require an insulation dam (wind- wash protection) at the perimeter of the attic, facing the soffits. In the past, code- minimum insulation requirements were woefully inadequate, and almost every cold- climate home leaked enough heat to generate ice dams. Many building inspectors, noting that attic insulation was code- compliant, falsely concluded that the only way to stop ice dams was by improving ventilation. In recent years, building codes have raised the bar on attic insulation. These days, if your ceiling is airtight and is insulated to the latest building code requirements, ice dams are far less likely. Wayne Tobiasson, a researcher at the Cold Regions Research and Engineering Laboratory in Hanover, New Hampshire, has for many years advised builders to use attic ventilation to address ice dams. Recently, however, Tobiasson has modified his advice. I have backed off of some of my statements about ventilating in cold regions,” Tobiasson explained at the 2. Westford Symposium on Building Science. As we increase the amount of insulation in roofs, there is less and less need to ventilate.”Although so- called hot roofs (roofs without any ventilation) can work well, ice dams can still form on a hot roof if the snow is deep enough. Very deep snow acts like insulation. If your roof is covered with two feet of fluffy snow, the bottom of the snowpack is insulated from cold outdoor temperatures. That raises the chance that melting will occur.)So, if your climate is very snowy, you probably want to stick with a cold (ventilated) roof.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
November 2017
Categories |